XM3.1-905-HPL
Power Supply Events
 
 

Alarms
 

Battery
 

Displayed time zone:
<<Prev 1 2 3 4 5 6 7 8 Next>>
Power Supply Events
  Time Event Description
270 2021-11-04 14:05:12 202A MINOR ALARM :XM3-1 INPUT FAIL ALARM=ALARM
269 2021-11-04 12:49:55 202B ALARM CLEARED :XM3-1 INPUT FAIL ALARM=OK
268 2021-11-04 12:49:49 202A MINOR ALARM :XM3-1 INPUT FAIL ALARM=ALARM
267 2021-11-04 12:31:18 202B ALARM CLEARED :XM3-1 NO BATTERIES =OK
266 2021-11-04 12:20:30 202E CLOCK DEFAULTED 12:20:30 11/04/21
265 2021-11-04 12:20:30 202B ALARM CLEARED :XM3-1 APP CLOCK NOT SET=0
264 2021-11-04 12:14:39 2029 MAJOR ALARM :XM3-1 NO BATTERIES =NO BATT
263 2021-11-04 12:15:51 2029 MAJOR ALARM :XM3-1 NO BATTERIES =NO BATT
262 2021-11-04 12:14:50 202A MINOR ALARM :XM3-1 BATT TEMP PROBE =ALARM
261 2021-10-29 19:54:17 202E CLOCK DEFAULTED 19:54:17 10/29/21
260 2021-10-29 19:54:17 202B ALARM CLEARED :XM3-1 APP CLOCK NOT SET=0
259 2021-10-29 19:48:44 202B ALARM CLEARED :XM3-1 BATT TEMP PROBE =OK
258 2021-10-29 19:48:26 202A MINOR ALARM :XM3-1 BATT TEMP PROBE =ALARM
257 2021-10-29 19:48:13 202A MINOR ALARM :XM3-1 BATT TEMP PROBE =ALARM
256 2021-10-29 19:48:13 202A MINOR ALARM :XM3-1 INPUT FAIL ALARM=ALARM
255 2021-10-29 19:47:51 2001 19:47:22 10/29/21 29s UTILITY EVENT: OUTAGE
254 2021-10-29 19:46:49 2001 19:46:29 10/29/21 20s UTILITY EVENT: OUTAGE
253 2021-10-29 19:46:01 2001 19:45:50 10/29/21 11s UTILITY EVENT: OUTAGE
252 2021-10-29 19:45:07 202B ALARM CLEARED :XM3-1 INPUT FAIL ALARM=OK
251 2021-10-29 19:44:59 2001 19:44:33 10/29/21 26s UTILITY EVENT: OUTAGE
250 2021-10-29 19:44:31 202A MINOR ALARM :XM3-1 INPUT FAIL ALARM=ALARM
249 2021-10-29 19:41:35 202B ALARM CLEARED :XM3-1 INPUT FAIL ALARM=OK
248 2021-10-29 19:41:26 2001 19:40:12 10/29/21 74s UTILITY EVENT: OUTAGE
247 2021-10-29 19:40:11 202E CLOCK DEFAULTED 19:40:11 10/29/21
246 2021-10-29 19:40:11 202B ALARM CLEARED :XM3-1 APP CLOCK NOT SET=0
245 2021-10-29 19:40:01 202A MINOR ALARM :XM3-1 INPUT FAIL ALARM=ALARM
244 2021-10-29 19:39:59 202B ALARM CLEARED :XM3-1 NO BATTERIES =OK
243 2021-10-29 19:34:21 2029 MAJOR ALARM :XM3-1 NO BATTERIES =NO BATT
242 2021-10-29 19:34:21 202A MINOR ALARM :XM3-1 BATT TEMP PROBE =ALARM
241 2021-10-29 19:34:06 2029 MAJOR ALARM :XM3-1 NO BATTERIES =NO BATT
240 2021-10-29 19:34:06 202A MINOR ALARM :XM3-1 BATT TEMP PROBE =ALARM
239 2021-10-29 19:31:51 2029 MAJOR ALARM :XM3-1 NO BATTERIES =NO BATT
238 2021-10-29 19:31:51 202A MINOR ALARM :XM3-1 BATT TEMP PROBE =ALARM
237 2021-10-29 19:32:15 2029 MAJOR ALARM :XM3-1 Low Batt Disconnect=FAST
236 2021-10-29 19:32:03 202A MINOR ALARM :XM3-1 INPUT FAIL ALARM=ALARM
235 2021-10-28 21:42:17 2038 ALARM CLEARED :XM3-1 ACTIVE DROP =0 NEW: 381W, OLD: 355W
234 2021-10-28 16:04:25 202B ALARM CLEARED :XM3-1 Low Batt Disconnect=OK
233 2021-10-28 15:59:00 202B ALARM CLEARED :XM3-1 INPUT FAIL ALARM=OK
232 2021-10-28 15:58:56 201A ALARM CLEARED :XM3-1 OUTPUT FAIL ALARM=OK
231 2021-10-28 15:42:22 201A MAJOR ALARM :XM3-1 OUTPUT FAIL ALARM=ALARM
230 2021-10-28 15:42:17 2038 WARNING :XM3-1 ACTIVE DROP =1 NEW: 0W, OLD: 357W
229 2021-10-28 15:42:15 2001 14:05:22 10/28/21 96m UTILITY EVENT: OUTAGE
228 2021-10-28 15:42:13 202B ALARM CLEARED :XM3-1 LOW BATTERY WARNING=OK
227 2021-10-28 15:42:13 2029 MAJOR ALARM :XM3-1 Low Batt Disconnect=STRING
226 2021-10-28 15:27:05 2029 MAJOR ALARM :XM3-1 LOW BATTERY WARNING=ALARM
225 2021-10-28 14:05:21 202A MINOR ALARM :XM3-1 INPUT FAIL ALARM=ALARM
224 2021-10-28 13:23:27 202E CLOCK DEFAULTED 13:23:27 10/28/21
223 2021-10-28 13:23:27 202B ALARM CLEARED :XM3-1 APP CLOCK NOT SET=0
222 2021-10-28 13:18:39 202B ALARM CLEARED :XM3-1 NO BATTERIES =OK
221 2021-10-28 13:17:36 2029 MAJOR ALARM :XM3-1 NO BATTERIES =NO BATT
220 2021-10-28 00:22:54 2038 ALARM CLEARED :XM3-1 ACTIVE DROP =0 NEW: 0W, OLD: 0W
219 2021-10-27 18:22:51 202B ALARM CLEARED :XM3-1 OUTPUT OVERLOAD =OK
218 2021-10-27 18:19:44 2029 MAJOR ALARM :XM3-1 OUTPUT OVERLOAD =ALARM
217 2021-10-27 18:18:15 202B ALARM CLEARED :XM3-1 Low Batt Disconnect=OK
216 2021-10-27 18:12:46 202B ALARM CLEARED :XM3-1 INPUT FAIL ALARM=OK
215 2021-10-27 18:12:42 201A ALARM CLEARED :XM3-1 OUTPUT FAIL ALARM=OK
214 2021-10-27 15:03:07 202B ALARM CLEARED :XM3-1 LOW BATTERY WARNING=OK
213 2021-10-27 15:02:16 201A MAJOR ALARM :XM3-1 OUTPUT FAIL ALARM=ALARM
212 2021-10-27 15:02:12 2038 WARNING :XM3-1 ACTIVE DROP =1 NEW: 0W, OLD: 381W
211 2021-10-27 15:02:10 2001 13:14:29 10/27/21107m UTILITY EVENT: OUTAGE
210 2021-10-27 15:02:08 2029 MAJOR ALARM :XM3-1 Low Batt Disconnect=STRING
209 2021-10-27 14:50:47 2029 MAJOR ALARM :XM3-1 LOW BATTERY WARNING=ALARM
208 2021-10-27 13:14:29 202B ALARM CLEARED :XM3-1 OUTPUT OVERLOAD =OK
207 2021-10-27 13:14:28 202A MINOR ALARM :XM3-1 INPUT FAIL ALARM=ALARM
206 2021-10-26 07:11:01 2029 MAJOR ALARM :XM3-1 OUTPUT OVERLOAD =ALARM
205 2021-10-26 03:21:02 2038 ALARM CLEARED :XM3-1 ACTIVE DROP =0 NEW: 381W, OLD: 355W
204 2021-10-25 21:43:11 202B ALARM CLEARED :XM3-1 Low Batt Disconnect=OK
203 2021-10-25 21:37:52 202B ALARM CLEARED :XM3-1 INPUT FAIL ALARM=OK
202 2021-10-25 21:37:48 201A ALARM CLEARED :XM3-1 OUTPUT FAIL ALARM=OK
201 2021-10-25 21:21:32 202B ALARM CLEARED :XM3-1 LOW BATTERY WARNING=OK
200 2021-10-25 21:21:07 201A MAJOR ALARM :XM3-1 OUTPUT FAIL ALARM=ALARM
199 2021-10-25 21:21:02 2038 WARNING :XM3-1 ACTIVE DROP =1 NEW: 0W, OLD: 362W
198 2021-10-25 21:21:00 2001 19:30:13 10/25/21110m UTILITY EVENT: OUTAGE
197 2021-10-25 21:20:58 2029 MAJOR ALARM :XM3-1 Low Batt Disconnect=STRING
196 2021-10-25 21:09:34 2029 MAJOR ALARM :XM3-1 LOW BATTERY WARNING=ALARM
195 2021-10-25 19:30:12 202A MINOR ALARM :XM3-1 INPUT FAIL ALARM=ALARM
194 2021-10-25 19:11:13 202E CLOCK DEFAULTED 19:11:13 10/25/21
193 2021-10-25 19:11:13 202B ALARM CLEARED :XM3-1 APP CLOCK NOT SET=0
192 2021-10-25 19:05:49 202B ALARM CLEARED :XM3-1 NO BATTERIES =OK
191 2021-10-25 19:05:23 2029 MAJOR ALARM :XM3-1 NO BATTERIES =NO BATT
190 2021-10-25 18:39:46 201A MAJOR ALARM :XM3-1 OUTPUT FAIL ALARM=ALARM
189 2021-10-25 18:39:42 2038 WARNING :XM3-1 ACTIVE DROP =1 NEW: 0W, OLD: 381W
188 2021-10-25 18:39:40 202B ALARM CLEARED :XM3-1 LOW BATTERY WARNING=OK
187 2021-10-25 18:39:40 2001 17:02:59 10/25/21 96m UTILITY EVENT: OUTAGE
186 2021-10-25 18:39:37 2029 MAJOR ALARM :XM3-1 Low Batt Disconnect=STRING
185 2021-10-25 18:24:36 2029 MAJOR ALARM :XM3-1 LOW BATTERY WARNING=ALARM
184 2021-10-25 17:02:57 202A MINOR ALARM :XM3-1 INPUT FAIL ALARM=ALARM
183 2021-10-25 16:11:52 202B ALARM CLEARED :XM3-1 NO BATTERIES =OK
182 2021-10-25 16:03:28 2029 MAJOR ALARM :XM3-1 NO BATTERIES =NO BATT
181 2021-10-25 15:48:58 202E CLOCK DEFAULTED 15:48:58 10/25/21
180 2021-10-25 15:48:58 202B ALARM CLEARED :XM3-1 APP CLOCK NOT SET=0
179 2021-10-25 15:48:36 202B ALARM CLEARED :XM3-1 NO BATTERIES =OK
178 2021-10-25 15:43:36 202B ALARM CLEARED :XM3-1 OUTPUT OVERLOAD =OK
177 2021-10-25 15:43:08 2029 MAJOR ALARM :XM3-1 OUTPUT OVERLOAD =ALARM
176 2021-10-25 15:43:08 2029 MAJOR ALARM :XM3-1 NO BATTERIES =NO BATT
175 2021-10-25 15:43:41 202A MINOR ALARM :XM3-1 INPUT FAIL ALARM=ALARM
174 2021-10-05 17:08:44 202E CLOCK DEFAULTED 17:08:44 10/05/21
173 2021-10-05 17:08:44 202B ALARM CLEARED :XM3-1 APP CLOCK NOT SET=0
172 2021-10-05 17:03:52 202B ALARM CLEARED :XM3-1 BATT TEMP PROBE =OK
171 2021-10-05 17:03:27 202A MINOR ALARM :XM3-1 BATT TEMP PROBE =ALARM
<<Prev 1 2 3 4 5 6 7 8 Next>>

 